momenta between the lab frame and the annihilation
frame was measured by finding the opening angle of the
emitted photons. Detectors were placed several meters
to either side of the sample at angles varying from 180°.
This is called angular correlation of annihilation radiation
(ACAR). Increasingly shallower anglesmeasure an increas-
ing momentum difference between the zero momentum
frame and the lab frame transverse to the direction of
travel of the emitted photons. The major drawback of
ACAR is extremely low count rates; this is due to the
small solid angle of the detector, which is a long distance
from the sample being studied. For this reason, Doppler-
broadening spectroscopic techniques are now used.
One measures the momentum difference in-line with the
emitted photons. In this case, one photon will have more
energy and appear blue-shifted due to the electron’s origi-
nal momentum in that direction, and the photon moving
in the opposite directionwill be red-shifted symmetrically
about the 511 keV peak. The detector can be placed right
beside the sample, which increases the detection rate by
orders ofmagnitude. Using twodetectors, thephotons can
be observed in coincidence, and background detections
can be dramatically reduced.
A number of detectors are placed as physically close to
the target as possible. The configuration of these detec-
tors varies depending on their purpose. Typically, at least
one cryogenically cooled high-purity germanium (HPGe)
detector is used because of its high energy resolution, and
often it is paired with another HPGe, or with a NaI(Tl) or
BaF
2
detector. The HPGe detectors have an energy reso-
lution of approximately 2.4 eV at 511 keV, and they are
absolutely necessary for Doppler-broadening spectrosco-
pies. The NaI(Tl) and BaF
2
detectors have a lower energy
resolution but a higher efficiency, and theyworkwell with
time-of-flight measurements or as coincidence counters.
CONCLUSION
Positron spectroscopies offer a level of precision for
defect detection and identification not available for any
other spectroscopic technique. Unfortunately, traditional
positron beams have a lower intensity than is viable for
time-sensitive commercial uses. To make the positron
beam a more useful tool for the semiconductor industry,
theDFPGhas beendeveloped, which increases the intensi-
ty of a traditional beam through a number of approaches.
An intense source of positrons for a beam can be
created by using a combination of a larger source, pre-
cisely etched moderator meshes, and an electrostatic
lensing system. It is designed to image moderated posi-
trons emitted from a thin, ring-shaped source. The size
and shape of the source allows for a larger amount of
radioactive material and therefore more positrons while
minimizing self-absorption and thermal breakdown. The
positrons emitted by the radioactive isotopes are focused
by the DFPG into a small spot of only a few millimeters.
REFERENCES
1. A. Ore and J.L. Powell:
Phys. Rev.,
1949,
75,
pp. 1696-99.
2. S. Berko and J. Mader:
Appl. Phys.,
1975,
5,
pp. 287-306.
3. B.Y. Tong:
Phys. Rev. B,
1971,
5,
pp. 1436-39.
4. R.M. Nieminen and J. Olivia:
Phys. Rev. B,
1980,
22,
pp. 2226-47.
5. C. Hugenschmidt et al.:
J. Phys.: Conf. Series,
2013,
443.
6. I.J. Rosenberg, A.H. Weiss, and K.F. Canter:
Phys. Rev. Lett.,
1980,
44,
pp. 1139-42.
7. B. Nielsen, K.G. Lynn, T.C. Leung, G.J. Van der Kolk, and L.J. Van
Ijzendoorn:
Appl. Phys. Lett.,
1990,
56,
pp. 728-30.
8. R. Krause-Rehberg and H.S. Leipner:
Positron Annihilation in Semi-
conductors,
Springer, 1999.
9. Z. von Borries:
Physik,
1942,
119,
p. 498.
10. P.J. Schultz and K.G. Lynn:
Rev. Mod. Phys.,
1988,
60,
pp. 701-81.
11. P. Coleman:
Positron Beams and Their Applications,
World Scientific,
2000.
12. A.P. Mills, Jr.:
Rev. Mod. Phys.,
1988,
60,
p. 704.
13. K.G. Lynn and H. Lutz:
Rev. Sci. Instrum.,
1980,
51,
p. 977.
14. S. Pendyala and J. McGowen:
J. Electron Spectrosc. Relat. Phenom.,
1980,
19,
p. 161.
15. A. Vahanem et al.:
Phys. Rev. B,
1987, p. 4506.
16. P.J. Schultz et al.:
Phys. Rev. B,
1983,
27,
p. 6626.
17. W. Anwand, J.M. Johnson, M. Butterling, W. Wagner, W. Skorupa, and
G. Brauer:
J. Phys.: Conf. Series,
2013,
443.
18. A.I. Williams et al.:
J. Appl. Phys.,
2015,
118,
p. 105302.
19. A.R. Koymen et al.:
Nucl. Instrum. Methods Phys. Res. A,
1999,
422,
pp. 479-83.
ABOUT THE AUTHORS
Manfred Fink
is a professor at the University of Texas at Austin in the Atomic, Molecular, and
Optical Physics Group. He began his career by studying electron diffraction and has expanded his
research to include novel uses of Raman spectroscopy to detect cancer, predict earthquakes, and
diagnose lactose intolerance in newborns; neutrino physics; and slow positron beam physics. Dr.
Fink has held a number of visiting professorships at universities in Germany and has been the chair
of the Texas chapter of the Humboldt Foundation.