Previous Page  31 / 58 Next Page
Information
Show Menu
Previous Page 31 / 58 Next Page
Page Background

edfas.org

31

ELECTRONIC DEVICE FAILURE ANALYSIS | VOLUME 19 NO. 2

CHARACTERIZING ORGANIC NANOCONTAMINATION

IN SEMICONDUCTORS BY RESONANCE-ENHANCED

NANOSCALE IR SPECTROSCOPY (AFM-IR)

Anirban Roy and Jay Anderson

Anasys Instruments Corp.

aroy@Anasysinstruments.com

EDFAAO (2017) 2:31-34

1537-0755/$19.00 ©ASM International

®

INTRODUCTION

For the last few decades, continuous development in

semiconductor process technology has led to the fabrica-

tion of deviceswith nanometer-scale features.

[1]

Growth in

the nanotechnology techniques used inproducingmicro-/

nano-electromechanical components results in a growing

interest for nanoscale surface analysis techniques that

can complement or may replace the currently available

tools. Resonance-enhanced AFM-IR is an emerging tech-

nique with the potential to overcome some limitations of

the existing tools used in semiconductor fabs and failure

analysis labs.

Organic contaminants are one of the major sources

of surface contamination in the process development

steps. Typical organic contaminants in the semiconductor

fabrication facility include residual photoresists, human

skin flakes, hair, and fabric from clothes and/or personal

protective equipment such as gloves, lab coats, masks,

and so on. Characterizing nanoscale organic contamina-

tion poses a major challenge to the traditional failure

analysis technique, as discussed below.

BACKGROUND

Scanning electron microscopy coupled with energy-

dispersive x-ray spectroscopy, one of the industry stan-

dards in surface analysis with nanometer-scale spatial

resolution, offers useful chemical insight into surface

defects and contamination; however, it providesminimal

information for organic components. Among other alter-

native analytical techniques, infrared (IR) spectromi-

croscopy provides superior results in identifying organic

materials but lacks spatial resolution. The traditional

mid-IR spectromicroscopic defect analysismethods offer

diffraction-limited detection resolution only up to 3 to

10

µ

m or larger.

[2]

Raman spectroscopy, on the other

hand, provides similar chemical insight with submicrom-

eter spatial resolution due to the short excitation wave-

lengths.

[3]

Nevertheless, the application of traditional

Raman spectromicroscopy in nanoscale defect analysis is

still limited due to experimental factors such as excitation

wavelength, depth of penetration, and the transparency

of microelectronic circuits.

Atomic force microscopy (AFM), a well-known scan-

ning probe imaging technique, yields high-spatial-

resolution topographic maps of a sample surface. Many

surface-imaging techniques based on AFM also provide

image contrast from material characteristics such as

surface mechanical, electrical, and magnetic properties.

While these properties can be mapped with high spatial

resolution and can provide critical insight into the surface

defects, none of these methods provide robust chemical

analysis, especially for unknown materials. However,

when a traditional AFM is combinedwith IR spectroscopy,

the resulting AFM-IR technique provides high-resolution

topographic maps with the addition of nanoscale chemi-

cal imaging and spectroscopy.

Previously, King et al. reported the applications of

AFM-IR technology innanoscale chemical andmechanical

“WHEN THE TRADITIONAL AFM IS

COMBINED WITH IR SPECTROSCOPY,

THE RESULTING AFM-IR TECHNIQUE

PROVIDES HIGH-RESOLUTION

TOPOGRAPHIC MAPS WITH THE

ADDITION OF NANOSCALE CHEMICAL

IMAGING AND SPECTROSCOPY.”