Curing cycle

Recommended cycle for FM 1000

film: Heat assembled samples in oven

to 340 ±10°F (170 ±6°C), and cure

them for 90 min. ±10 min. at the tem-

peratures at bond line of 340 ±10°F

(170 ±6°C). Curing conditions may

vary based on manufacturer recom-

mendations and for different types of

glue. Control the curing temperature

with calibrated thermocouple touching

(or bonding to) assembled samples.

Class 5 furnace (per AMS2750) with

temperature uniformity in the working

zone of ±25°F is sufficient.

Fixture

Figure 3 shows a V-grooved gravity fixture. Such a

design is working with FM1000 adhesive film. To keep

assembled samples in compression during glue curing,

one solid steel cylinder (1 in. diam. by 2 in. long) must

be placed on top of two assembled samples. Fixture

could be made from steel or an aluminum alloy, and

should support samples at 30° to vertical position. The

horizontal groove in the middle of the fixture shown in

Fig. 3 protects it from contact with excessive glue during

the curing process.

Work in clean and controlled environment

Protect samples from contamination: Do not touch

coated surface. Keep coated samples in clean envelopes;

plastic is recommended. Use filtered compressed air when

removing grit, or dry sample surfaces from liquid de-

greaser. Protect samples from excessive humidity.

Verify alignment

Sample misalignment always leads to low test results.

Verify their alignment in the fixture before curing, and after

curing and removing excessive glue from the sample sides.

Use tensile machine with universal joints to ensure sample

self-alignment when tensile load is applied.

Control load by applying speed

Recommended crosshead speed for tensile load is

0.03–0.05 in./min.

Number of coated samples

It is recommended to test five samples and identify the

coating bond strength as an average of the five results. For

well-established dense coatings with high adhesion and co-

hesion strength (such as cermets), sample number can be

reduced to three for one data point.

Test reference samples (glue test)

Always test at least one uncoated reference sample with

each set of curing samples to verify/confirm that the glue

itself has sufficient bond strength (10,000 psi as a mini-

mum for FM1000).

Keep records

Keep records of all test conditions and file test reports.

Bond test reports should include as a minimum: glue

strength; coating bond strength; percent of each mode of

coating failure (see Fig. 2); test date; operator name/sig-

nature; reference on applicable standard(s), specifica-

tions, and local instructions documenting test conditions

and requirements.

This accepted practice is intended to be used as a

baseline for your test processes, but does not replace

local test/lab instructions. Additional requirements may

apply based on available equipment, testing materials,

and customer specifications. Acceptance testing should

always be performed in accordance with ASTM C633

(latest revision).

iTSSe

Possible failure locations

Glue adhesion failure/

Bond slug interface

Glue cohesive failure/Middle

Glue/Top coat adhesion failure

Top coat cohesive failure

Top coat/Bond coat adhesion

failure

Bond coat cohesive failure

Bond coat adhesion failure

Glue failure*

Double coating

GS

GM

GC

TC

CC

BC

BB

GF

Single coating

GS

GM

GC

CF

BB

GF

Glue

Top coat

Bond coat

Glue

Button

Fig. 2 —

Bond test failure map for coating (s) applied on cylindrical button.

Courtesy of Sulzer Metco Inc.

Fig. 3 —

Gravity fixture to assemble and cure bond test

samples. Picture does not show steel cylinders on top of

assembled samples. One steel cylinder (1 in. diam. by 2 in.

long) on top of each assembly is sufficient to bond FM1000

to samples

Mating cap

FM 1000

Bond cap

(coating

on top)