May_EDFA_Digital

edfas.org 19 ELECTRONIC DEVICE FAILURE ANALYSIS | VOLUME 20 NO. 2 Both TIVA/OBIRCH and CPA are laser stimulation techniques, [8] which capture the change in the electrical characteristic of the circuit being illuminated by a focused laser beam. The effect is two-fold and varies according to the laser’s wavelength. The 1064-nm laser causes more generation of electron-hole pairs, while the 1340-nm laser causes more thermal effect. Both are effective in fault localization and can be applied to various laser stimulation techniques to capture the changes in differ- ent electrical characteristics. TIVA captures the change in voltage of a device biased at a constant current through the thermal-conductive effect, whileOBIRCHmonitors the change in current of a device biased at a constant voltage. Figure 2 is a diagram of a TIVA setup. Both TIVA/OBIRCH are capable of isolating ohmic short faults due to large resistance changes caused by the thermal effect when a near-infrared laser shines on the shorts. CPA, also known as soft defect localization (SDL), [18] is a tester-based laser stimulation fault isolation technique. Figure 3 is a diagram of a CPA setup. CPA captures the change between the fail and pass status of a device under a repeated test pattern loop while the laser is scanned across the device. As the laser moves pixel-by-pixel, the tester provides apass/fail signal back to the laser scanning microscope. CPA can be labeled “positive” or “negative” depending on the laser induced change between the pass and fail status of the device under test. If theDUT is operat- ing in a failing conditionwithout the laser shining, and the laser causes it to pass, the CPA is considered “positive.” If the DUT is operating in a passing condition, and the laser causes it to fail, the CPA is considered “negative.” Therefore, CPA is the most suitable method for isolating the faults of soft failures. Althougha laser scanningmicroscope is alsoemployed for LVI/LVP, the technique is quite different from TIVA or CPA. Instead of detecting the electrical characteristic change through the biased pins on the DUT, this tech- nique monitors the modulation in the reflected laser beam from the active regions, such as drain and channel through silicon backside. Figure 4 is a simple diagram of the LVI/LVP setup. The LVI detector collects data in the frequency-domain from numerous points in the field of view. The resulting image (frequency map) can be over- laid onto the reflected image, creating a map showing Fig. 1 Diagram of a PEM setup. Fig. 2 Diagram of a TIVA setup. Fig. 3 Diagram of a CPA setup.

RkJQdWJsaXNoZXIy MjA4MTAy