February_EDFA_Digital

edfas.org ELECTRONIC DEVICE FAILURE ANALYSIS | VOLUME 20 NO. 1 34 SOLUTIONS From the analysis above, to cope with start-up over- shoot, many techniques can be adopted, such as shorten- ing the working time of the ICSC, increasing the start-up Fig. 2 Proposed start-up overshoot suppression circuitry Fig. 3 Converter’s start-up without EMI filter or ICSC Fig. 4 Converter’s start-up with EMI filter and ICSC Fig. 5 Converter’s start-up with overshoot suppression circuitry delay time, increasing the start-up time, and improving the transient response performance. Shortening the working time of the ICSC will lead to high input inrush current. Limited by the DC/DC converter’s output LC filter and error amplifier, the bandwidth of the controlled closed loop cannot be improved significantly, meaning that the transient response performance cannot be improved sharply. This article advises increasing the start-up delay time, T d , and increasing the start-up time, T s , to solve start-up overshoot. For packed hybrid DC/DC converters, increasing the start-up time cannot be done except by decapsulating the converter to revise the internal circuit. Adding an external start-up delay circuitry is one of the choices. Figure 2 shows one circuit design. It applies to the converter that cannot work if its inhibit pin is connected to the input return line. It sacrifices input voltage range to increase start-up delay time. Without this circuit, the DC/DC converter starts up at V in1 . With this circuit, it starts

RkJQdWJsaXNoZXIy MjA4MTAy