edfas.org 33 ELECTRONIC DEVICE FAILURE ANALYSIS | VOLUME 20 NO. 1 in the positive supply line. The most common and basic ICSC in Chinese space electronic systems is shown in Fig. 1. It is an n -channel enhancement MOSFET-based ICSC and is used as an illustration to simplify the analy- sis. MOSFET Q1’s DC input resistance is extremely high. When the power bus V in is applied through a switch S1, due to C1, V1 increases from 0 V to V in with a dura- tion T tr of several milliseconds. The relationship of V1, t , and V in can bewritten as V in is more than the gate threshold voltage of MOSFET Q1. R3 is low, aimed to damp the ringing of C1 and the gate inductance. V2 is almost equal to V1, and thus V2 increases from 0 V to V in , which is more than the gate thresh- old voltage of Q1, within this duration Tr. Q1 turns on as V2 increases tomore than the gate threshold voltage. The equivalent circuit of drain-to-source for MOSFET Q1 is similar to a varistor. Drain-to-source resistance decreases from a million ohms to on-state resistance. Therefore, the input line voltage to the EMI filter and hybrid DC/DC converter V inf is ramped to almost V in . V inf can be approxi- mately calculated as V inf = k t , where k is the ramp rate, and t is time. Typical input line voltage rise time is 5 ms. With input line voltage ramped, the input inrush current is reduced to several amps, which is acceptable for space- craft power bus. However, some converters start up in a short time. The start-up delaying time, T d , plus the start-up time, T s , is on the order of milliseconds. The overall time is less than the working time, T op(ICSC) , of the ICSC. That is: T d + T s < T op(ICSC) (Eq 1) Because all DC/DC converters can operate in a wide range of input voltage, whenDC/DC converters are applied in the power systemwith an EMI filter and ICSC, they begin towork in their input line voltage ramp. At this time, a DC/ DC converter’s input voltage is lower than the final input voltage. The DC/DC converter’s start-up delaying time plus start-up time is less than the working time, T op(ICSC) , of the ICSC. After the DC/DC converter’s start-up, the DC/DC converter’s internal soft-start circuit will not limit its duty cycle, and its duty cycle is determined only by its internal control loop. Because the DC/DC converter’s input voltage is lower than the final in the input line voltage ramp, it works with the duty cyclemore than the normal, perhaps maximum duty cycle. This working state will go on until the internal controlled closed loop regulates the output voltage again. The normal bandwidth of the controlled closed loop is several kilohertz, with regulating time on the order of milliseconds. During the input voltage ramp, the DC/DC converter’s duty cycle should decrease to the corresponding value in time. However, under the mil- liseconds regulating time limit, the closed loop cannot decrease the duty cycle in time, and thus the overshoot occurs. In a switching DC/DC converter, neglecting the switch device’s on-state voltage drop and the rectifier’s forward voltage drop, the relationship of input voltage ( V in ), primary winding turns ( N P ), secondary winding turns ( N S ), duty cycle (D), and output voltage ( V O ) is: V O = V in × × D (Eq 2) FromEq 2, if the duty cycle, D, cannot decrease in time as the input voltage, V in , increases, the output voltage, V O , will increase. If it occurs at start-up, it is just start-up over- shoot. If the controlled loop’s regulating time, T reg , is lower than the ICSC’s working time, T op(ICSC) , minus the DC/DC converter’s start-up delaying time, T d , and start-up time, T s , the overshoot voltage, OV(%), can be approximately calculated as: T reg < T op(ICSC) − T d − T s (Eq 3) OV(%) = × 100% (Eq 4) . Fig. 1 Typical hybrid DC/DC converter application circuitry

RkJQdWJsaXNoZXIy MjA4MTAy