edfas.org 27 ELECTRONIC DEVICE FAILURE ANALYSIS | VOLUME 20 NO. 3 the same result as the scans: Applying a positive voltage to the tip results in a similar current on both contacts, while applying a negative voltage to the tip shows a strong discrepancy in the resulting current, depending onwhich contact is being observed. Further investigations including site-specific TEM analyses and subsequent energy-dispersive x-ray (EDX) investigationswere performed to elucidate the root cause for the observed phenomena. Results indicate that the increased leakage is related to the penetration depth of the contacts through the SiGe-interlayer region and cor- responding implants (Fig. 6). CASE #3: BACK END OF LINE (BEOL) OPEN ISSUE ON COPPER PLATING RECIPE DEVELOPMENT WAFER A¨er an environmental stress test, ametal-7 via chain from a copper plating recipe development wafer failed (open) and was analyzed. The failing via chain process monitor structures did not show passive voltage contrast (PVC) signals during the fab in-line electron beam inspec- tions. The same condition was observed when both PVC and active voltage contrast (AVC) were conducted on the device in the SEM (Fig. 7). The “high resistance” open failures on the via chain structure at metal 7 was isolated using the SEM in-situ RCI/EBAC technique. The gradual change in resistance (contrast) was observed at the defect site (white arrow) when the samplewas scannedwith the SEMbeamvoltage of 2kV, beam current of 6.4 nA, and scan rate of 30 µs (Fig. 8). The same signal was enhanced when the signal polarity was swapped on the macro structure (Fig. 9). FIB cross sections of the RCI site showed varying Fig. 6 TEM and EDX analyses of various contacts exhibiting di’erent current responses (red: W, yellow: Ni, and blue: Ge). Fig. 7 No contrast change was observed when in-situ SEM PVC and AVC analyses were done on the via chain structures at metal 7. One of the pads was grounded by milling a 1 × 10 µm hole in the pad. Fig. 8 The RCI/SEM overlay image of the via chain process monitor test structure at metal 7 with the RCI amplifier probe (visible) on pad 25 and ground probe (not visible) on pad 24. The via chain structure shows a gradual contrast change at the defect site (white arrow) when analyzed. Fig. 9 RCI/SEM overlay image of test structure with RCI probe (visible) on pad 24 and pad 25 grounded (not visible). Contrast changewasmorepronouncedwhen the bias polarity was reversed on the structure. (continued on page 30)

RkJQdWJsaXNoZXIy MjA4MTAy