May_EDFA_Digital

edfas.org 45 ELECTRONIC DEVICE FAILURE ANALYSIS | VOLUME 20 NO. 2 and 1000Base-T1 specifications for physical media attachment, physical layer solutions, and physical coding sublayer. All four software options automate compliance with 100% test coverage for all tests in the automotive physical layer BroadR-Reach, 100Base-T1, and 1000Base- T1 specifications, respectively. These automotive Ethernet test software packages automatically execute tests and display results in a flex- ible report format. In addition to measurement data, the report provides amargin analysis that shows how closely the devices passed or failed each test. The automotive Ethernet electrical compliance solutions perform a com- plete set of electrical tests to meet the BroadR-Reach, 100Base-T1, and/or 1000Base-T1 specifications: • Transceiver testing for BroadR-ReachV3.2and100Base- T1 (IEEE 802.3bw) specifications • Receiver testing for BroadR-Reach V3.2 and 100Base-T1 (IEEE 802.3bw) specifications • Transceiver testing for 1000Base-T1 (IEEE 802.3bp) specifications • Protocol trigger anddecode for BroadR-Reach V3.2 and 100Base-T1 (IEEE 802.3bw) specifications • Link testing for BroadR-Reach V3.2 and 100Base-T1 (IEEE 802.3bw) specifications For more information, visit keysight.com . INOVENSO INTRODUCES IEM DESKTOP SEM Inovenso, Istanbul, introduces its IEMSeries of desktop scanning electron microscopes. The biggest advantages of Inovenso’s benchtop SEMs over conventional SEMs is process rapidity. With Inovenso’s SEMs, results can be obtained within four minutes, compared with 30minutes for conventional SEMs. The price difference is also consid- erable, as thebenchtopSEMs enable users toachieve 5 nm resolution results (similar to a full-sized SEM) with a price that is three times more affordable. Another advantage is that the benchtop SEM doesn’t require any infrastruc- ture—just a table and a plug. The SEMoscope tabletop SEM combines imaging power up to 150,000 × magnification rate and outstand- ing technical performance with better depth of focus and chemical contrast: Integrated EDS analysis. The SEMoscope + Series high level tabletop SEMs offer integrated, powerful EDSmicro- analysis withNORANSystem7 specialized for SEMoscope spectral imaging. Further, the UltraDry Compact EDS detector provides outstanding elemental mappingwithin a few minutes. With spectral imaging, where a full EDS spectrum is stored at every pixel, samples can be ana- lyzed after they have been removed from themicroscope. NORANSystem7 tools provide several analytical methods for best results. Both Oxford and EDAX brands of EDS detectors can be integrated into the SEMoscope dekstop SEM models depending on user needs. RemovableBSEdetector. Byapplying the4-channel BSE detector, composition and topography functions are avail- able. These functions are optional and can be opted out. ION coater and cool stage. During SEM analysis, the specimen is irradiated with an electron beam, which causes an accumulation of electric charges on the speci- men surface and decreasing image quality. In order to obtain high quality images of nonconductive samples via SEM, it is necessary to create a conductive layer on the surface. The conductive coating shields the sample from the surface charge and provides a ground-potential surface, eliminating electric fields outside the sample. For more information, visit semoscope.com . Keysight’s automotive Ethernet receiver compliance test solution. Inovenso’s benchtop SEM.

RkJQdWJsaXNoZXIy MjA4MTAy