Feb_EDFA_Digital

edfas.org ELECTRONIC DEV ICE FA I LURE ANALYSIS | VOLUME 25 NO . 1 26 A great product idea is no guarantee of a successful business. As a third-party provider, there is the added challenge of OEM partner buy-in and management. It could have gone wrong in somany ways, and it nearly did more than once. Ultimately, we prevailed with a tool so elegant, that even a microbiologist like me could use it. Today, the industry-transforming Omniprobe technology lives on in theOmniProbemodel 350 and 400manipu- lators of Oxford Instruments. The semiconductor and microscopy industries owe a debt of gratitude to Tom Moore for his grit, courage, and perseverance to stickwith the in situ lift-out dream, despite great personal financial risk in unprecedented and challenging historical times. I am sure other lift-out inventors have equally fascinating stories to share, and I hope we get to hear them. ACKNOWLEDGMENTS This article is dedicated to two groups of people. First and foremost, I recognize and thank my Omniprobe cofounders Tom Moore and Rocky Kruger, as well as the talented individuals that worked at Omniprobe from logistics to engineering to sales and service. I include Omniprobe’s contractors, distributors, andco-opstudents. Theywere able to design, build, and deliver products with exceptional performance, customer support, and service, even across the major economic downturns of 2001 and 2009. Secondly, I want to recognizemy industry peers and competitors who also did their part to drive the industry forward. I have beenblessed toworkwith andwalk among the industry’s best talent, withmany interactions enabled by EDFAS and ISTFA. We work in a demanding business, and anyone who has been successful with execution of FIB lift-out solutions and services has my recognition and respect. Lastly, I’d like to thank Monica Vargas for being Omniprobe’s first customer and agreeing to share her name for this article. REFERENCES 1. T. Ishitani, et al.: “Focused‐ion‐beam ‘‘Cutter’’ and ‘‘Attacher’’ for Micromachining and Device Transplantation,” Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena, 1991, Vol. 9, No. 5, p. 2633-2637, doi: 10.1116/1.585661. 2. T. Ohnishi, Y. Kawanami, and T. Ishitani: “Proposal for Device Transplantation using a Focused Ion Beam,” Japanese Journal of Applied Physics, 1990, Vol. 29, No. 1A, p. L188. 3. L.A. Giannuzzi: Introduction to Focused Ion Beams: Instrumentation, Theory, Techniques and Practice, Springer Science &Business Media, 2004. 4. E. Kirk: “Cross-sectional Transmission Electron Microscopy of Precisely Selected Regions from Semiconductor Devices,” in Inst. Phys. Conf. Ser., 1989, Vol. 100, p. 501-506. 5. R. Henderson and M. Alsari: “History of Cryo-EM,” Scientific Video Protocols, Vol. 1, Vo. 1, p. 1, 2020/6/1 2020, doi: 10.32386/scivpro. 000022. 6. J. Dubochet andA. McDowall: “Vitrificationof PureWater for Electron Microscopy,” Journal of Microscopy, 1981, Vol. 124, No. 3, p. 3-4. 7. J. Dubochet: “A Reminiscence about Early Times of Vitreous Water in Electron Cryomicroscopy,” Biophysical Journal, 2016, Vol. 110, No. 4, p. 756. 8. J. Dubochet: 2017 [Online Multimedia]. Accessed: June 13, 2022 at https://www.nobelprize.org/uploads/2018/01/dubochet-lecture.pdf. 9. T.M. Moore: “Apparatus and Method for Automated Non-destructive Inspection of Integrated Circuit Packages,” U.S. Patent 5627320, https://patents.google.com/patent/US5627320A. 10. T.J. Shaffner: “Characterization Challenges for the ULSI Era, Diagnostic Techniques for Semiconductor Materials and Devices (invited) Abstract #449,” The Electrochemical Society, Inc. Spring Meeting, Montreal, Canada, P. Rai-Choudhury, J.L. Benton, D.K. Schroder, and T.J. Shaffner, Eds., Presented May 6-8, 1997, Vol. PV 97-12, Montreal, Quebec, Canada, p. 1. 11. Hitachi High-Tech, “Notice of Patent Infringement Lawsuit Against FEI Japan [Press Release],” 2009, Accessed 09-04-2022 at https://www. hitachi-hightech.com/global/about/news/2009/20091106_2.html. 12. Hitachi High-Tech, “Hitachi High-Tech and FEI Settle Patent Infringement Case [Press Release],” 2012. Accessed 09-04-2022 at https:// www.hitachi-hightech.com/global/about/news/2012/nr20120821. html. 13. L.A. Giannuzzi and T.E. Clark: “Optimizing Van der Waals Forces For FIB ex situ Lift Out,” Microscopy and Microanalysis, 2017, Vol. 23, p. 306-307. 14. C.D.J. Parmenter, M.W. Fay, C. Hartfield, and H.M. Eltaher: “Making the Practically Impossible ‘Merely difficult’—Cryogenic FIB Liftout for ‘Damage free’ Soft Matter Imaging,” Microscopy Research and Technique, 2016, Vol. 79, No. 4, p. 298-303, doi: https://doi. org/10.1002/jemt.22630. 15. M.J. Zachman, E. Asenath-Smith, L.A. Estroff, and L.F.Kourkoutis: “Site-Specific Preparation of Intact Solid–Liquid Interfaces by Label-Free In Situ Localization andCryo-Focused IonBeamLift-Out,” Microscopy andMicroanalysis, 2016, Vol. 22, No. 6, p. 1338-1349, doi: 10.1017/S1431927616011892. 16. N. Antoniou: “Failure Analysis of ElectronicMaterial Using Cryogenic FIB-SEM,” EDFA Magazine, 2013, Vol. 15, No. 3, p. 12-19. 17. C. Parmenter and Z. Nizamudeen: “Cryo-FIB-lift-out: Practically Impossible to Practical Reality,” Journal of Microscopy, 2021, Vol. 281, No. 2, p. 157-174, doi: https://doi.org/10.1111/jmi.12953. 18. M.J. Zachman, et al.: “Cryo-STEMMapping of Solid-liquid Interfaces andDendrites inLithium-metal Batteries,” Nature, Aug. 2018, Vol. 560, No. 7718, p. 345-349, doi: 10.1038/s41586-018-0397-3. 19. T. Ohnishi and T. Ishitani: “Method for Separating Specimen and Method for Analyzing the Specimen Separated by the Specimen Separating Method,” U.S. Patent 5270552A, 1993, Available: https:// patents.google.com/patent/US5270552A. 20. T. Moore, R. Kruger, and C. Hartfield: “Method for Sample Separation andLift-outwithOneCut,”U.S. Patent 6420722, 2002, https://patents. google.com/patent/US6420722B2. 21. T. Moore: “Total Release Method For Sample Extraction From A Charged-Particle Instrument,” U.S. Patent US6570170B2, 2003, https://patents.google.com/patent/US6570170B2. 22. C. Hartfield, et al.: “Variations on FIB in situ Lift-Out for TEM Sample Preparation,” 2011, Vol. 13, No. 3, p. 18-26. 23. https://en.wikipedia.org/wiki/Dot-com_bubble. 24. F. Meisenkothen, M. Dawson, and C. Hartfield: “Preparation of Nanowire Specimens for Atom Probe Tomography,” http://www. fibsem.net/web_documents/2015Presentations/Meisenkothen.pdf (accessed September 05, 2022). 25. T. Ohnishi, et al.: “ANewFocused IonBeamMicrosamplingTechnique for TEM Observation of Site-specific Areas,” ISTFA 1999: ASM International, p. 449-453.

RkJQdWJsaXNoZXIy MTMyMzg5NA==